Rely-AMP MLL-AF4
quantitative detection
The chromosomal translocation occurring between the band 21 of the long arm of chromosome 4 and band 23 of the long arm of chromosome 11 t(4;11)(q21;q23) and leading to the generation of the fusion gene MLL-AF4 is one of the most recurrent chromosomal aberrations observed in acute lymphoblastic leukemia (ALL). However, a diagnosis of t(4;11)(q21;q23)/MLL-AF4 positive ALL in adult patients is a rare event, considering the relative low incidence of ALL in adult population.
The incidence of t(4;11)(q21;q23)/MLL-AF4 positive ALL has a characteristic bimodal age distribution with a major peak in early infancy, occurring in over 50% ALL cases in infants aged less than 6 months, in 10–20% of older infants, in about 2% of children, and in almost 10% of adults.
DETAILS
Rely-AMP MLL-AF4 is an in vitro Real Time polymerase chain reaction assay for the direct, quantitative detection MLL-AF4 fusion transcript. Housekeeping gene ABL is a reference for relative quantitation. Rely-AMP MLL-AF4 provides all necessary reagents for RNA extraction, reverse transcription and cDNA detection.
TECHNICAL SPECIFICATIONS
Quantitative/qualitative |
Quantitative
|
Extraction |
Guanidinium-phenol
|
Technology
|
Real time PCR
|
Sample type |
Blood
|
Thermal cycler |
optimized with CFX96 (Bio-Rad) but designed for use with real-time devices from various manufacturers
|
Housekeeping gene
|
ABL
|
Fluorophore
|
FAM - HEX
|
Processing |
Manual
|
Time to result |
2 hours (after extraction)
|
PERFORMANCE
Analytical sensitivity-detection limit: 1 leukemic cell/105 normal cells
Analytical Specificity: No cross-reactivity
Diagnostic sensitivity:95,3%
Diagnostic specificity: 100%
Rely-AMP MLL-AF4
qualitative detection
Rely-AMP MLL-AF4 qualitative detection is an in vitro polymerase chain reaction assay for the direct detection MLL-AF4 traslocation e8-e7, e8-e4, e9-e5, e9-e4, e10-e6, e10-e5, e10-e4, e11-e6, e11-e5, e11-e4. Rely-AMP T MLL-AF4 provides all necessary reagents for RNA extraction, reverse transcription and cDNA detection.
TECHNICAL SPECIFICATIONS
Quantitative/qualitative |
Qualitative
|
Extraction |
Guanidinium-phenol
|
Technology
|
Nested RT-PCR
|
Sample type |
Blood
|
Thermal cycler |
optimized with CFX96 (Bio-Rad) but designed for use with real-time devices from various manufacturers
|
Control
|
β-actine
|
Processing |
Manual- Agarose gel
|
Time to result |
3 hours (after extraction) |
ORDERING INFORMATION
PRODOTTO |
CAT.NO. |
COSTO |
Rely-AMP MLL-AF4 extraction and detection kit |
TTAF4-50 |
Contact us |
Rely-AMP MLL-AF4 detection kit |
TTAF4-50D |
Contact us |
Rely-AMP MLL-AF4 qualitative extraction and detection kit |
LTAF4-50 |
Contact us |
Rely-AMP MLL-AF4 qualitative detection kit |
LTAF4-50D |
Contact us |